the ventilation structure Research of permanent magnet traction motor used in Rail transportation
Clicks: 91
ID: 135617
2017
In order to effectively improve the ventilation performance of permanent magnet synchronous traction motor used in the rail transit,this paper,taking a 600 kW permanent magnet synchronous traction motor as an example,and based on computational fluid dynamics ( CFD) and the basic theory of heat transfer,establishes the three dimensional physical model under its ventilation scheme for the analysis of temperature field. Applying the finite volume element method,each part of the permanent magnet synchronous traction motor was numerical analyzed. And the temperature distribution of its internal components was summarized in order to optimizing. It provides the theory basis forimproving the permanent magnet traction motor cooling performance as well as the accurate calculation for temperature field of the permanent magnet traction motor with larger capacity.
Reference Key |
shu-ye2017journalthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | ;DING Shu-ye; LI Shan-shan; YANG Fan;CHEN Wei-jie |
Journal | journal of harbin university of science and technology |
Year | 2017 |
DOI | 10. 15938 /j. jhust. 2017. 03. 016 |
URL | |
Keywords | Keywords not found |