otimização e validação da técnica de extração líquido-líquido com partição em baixa temperatura (ell-pbt) para piretróides em água e análise por cg optimization and validation af liquid-liquid extraction with the low temperature partition technique (lle-ltp) for pyrethroids in water and gc analysis

Clicks: 163
ID: 193537
2007
The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.
Reference Key
vieira2007qumicaotimizao Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Heulla Pereira Vieira;Antônio Augusto Neves;Maria Eliana Lopes Ribeiro de Queiroz
Journal greece and rome
Year 2007
DOI 10.1590/S0100-40422007000300006
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.