validation of actiwatch for assessment of sleep-wake states in preterm infants
Clicks: 206
ID: 226870
2014
Purpose: The purpose of this study was to validate the Actiwatch with behaviorally determined sleep–wake state in preterm infants and to explore the influence of postmenstrual age on the accuracy of Actiwatch.
Methods: A prospective and comparative research design was used. Twenty-four preterm infants with postmenstrual age ranging from 28–38 weeks were studied. The infants were studied for 2 hours between two feedings. Infant's sleep and wake state was measured every 30 seconds using Actiwatch and the Anderson Behavioral State Scale simultaneously.
Results: Actiwatch demonstrated high agreement, sensitivity, and predictivity of sleep state, when validated with the Anderson Behavioral State Scale at the setting of high and automatic activity thresholds, and was not influenced by the infant's postmenstrual age. However, lower specificity and predictivity were found in the wake state, and influenced by postmenstrual age.
Conclusion: Results of this study suggest that high activity thresholds are the most accurate for determining sleep state in preterm infants, and health care professionals must take the limitations into consideration while using the Actiwatch to assess wake states.
Reference Key |
msn2014asianvalidation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | ;Shu-Chen Yang, RN, MSN;Asphodel Yang, RN, PhD;Ying-Ju Chang, RN, PhD |
Journal | fungal genetics and biology : fg & b |
Year | 2014 |
DOI | 10.1016/j.anr.2014.06.002 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.