heat transfer enhancement in tubular heat exchanger with double v-ribbed twisted-tapes

Clicks: 184
ID: 258053
2016
An experimental work on heat transfer enhancement in a round tube by insertion of double twisted tapes in common with 30° V-shaped ribs has been conducted. Air as the test fluid flowed through the test tube having a constant wall heat-flux with Reynolds number (Re) from 5300 to 24,000. The combined vortex generators (called “V-ribbed twisted tape”) were obtained by incorporating V-shaped ribs into the edges of double co-twisted tapes having a similar twist ratio of 4. The effect of pertinent V-rib parameters such as four relative rib heights, (called “blockage ratio”, BR=b/D= 0.07, 0.09, 0.14 and 0.19) and a relative rib pitch, (PR=P/D=1.9) at an attack angle of rib, α=30° on thermal characteristics was investigated. The experimental results reveal that the heat transfer and pressure drop in terms of the respective Nusselt number and friction factor for the V-ribbed twisted tapes show the increasing trend with the rise of Re and BR. The V-ribbed twisted tape with BR=0.19 yields the highest heat transfer and friction factor. However, the maximum thermal enhancement factor is about 1.4 for the V-ribbed twisted tape at BR=0.09 but is around 1.09 for the twisted tape with no rib.
Reference Key
tamna2016caseheat Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Sombat Tamna;Yingyong Kaewkohkiat;Sompol Skullong;Pongjet Promvonge
Journal gateways : international journal of community research & engagement
Year 2016
DOI 10.1016/j.csite.2016.01.002
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.