Micromegas in CAST and prospects

Clicks: 127
ID: 273161
2006
A low background Micromegas X-ray detector has been used to search for solar axions in the CAST experiment at CERN. The detector has an active area of 7cm times 7cm, excellent spatial resolution (~70nm), and good energy resolution. It is built using low radioactivity materials and the obtained background level is below 5times10 -5 counts/keV/cm 2 /s. The detector is being upgraded for the second phase of the experiment (2006-2007) with a reduced active area. A focusing X-Ray optic and improved shielding will be used to further reduce the background by approximately two orders of magnitude.
Reference Key
zaffanela20062006micromegas Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors P. Abbon,S. Andriamonje,S. Aune,D. Besin,S. Cazaux,Theopisti Dafni,T. Decker,B. O. Dogan,N. Duportail,G. Fanourakis,E. Ferrer Ribas,J. Galan Lacarra,T. Geralis,M. Gros,A. Giganon,I. Giomataris,R. Hill,I. G. Irastorza,K. Kousouris,J. Morales,T. Papaevangelou,Michael Pivovaroff,M. Riallot,J. Ruz Armendariz,R. Soufli,K. Van Bibber,K. Zachariadou,G. Zaffanela;P. Abbon;S. Andriamonje;S. Aune;D. Besin;S. Cazaux;Theopisti Dafni;T. Decker;B. O. Dogan;N. Duportail;G. Fanourakis;E. Ferrer Ribas;J. Galan Lacarra;T. Geralis;M. Gros;A. Giganon;I. Giomataris;R. Hill;I. G. Irastorza;K. Kousouris;J. Morales;T. Papaevangelou;Michael Pivovaroff;M. Riallot;J. Ruz Armendariz;R. Soufli;K. Van Bibber;K. Zachariadou;G. Zaffanela;
Journal 2006 ieee nuclear science symposium conference record
Year 2006
DOI 10.1109/nssmic.2006.353827
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.