Monte Carlo simulation of photon buildup factors for shielding materials in radiotherapy x-ray facilities.

Clicks: 215
ID: 51326
2013
This paper presents the results of a series of calculations to determine buildup factors for ordinary concrete, baryte concrete, lead, steel, and iron in broad beam geometry for photons energies from 0.125 to 25.125 MeV at 0.250 MeV intervals.Monte Carlo N-particle radiation transport computer code has been used to determine the buildup factors for the studied shielding materials.The computation of the primary broad beams using buildup factors data was done for nine published megavoltage photon beam spectra ranging from 4 to 25 MV in nominal energies, representing linacs made by the three major manufacturers. The first tenth value layer and the equilibrium tenth value layer are calculated from the broad beam transmission for these nine primary megavoltage photon beam spectra.The results, compared with published data, show the ability of these buildup factor data to predict shielding transmission curves for the primary radiation beam. Therefore, the buildup factor data can be combined with primary, scatter, and leakage x-ray spectra to perform computation of broad beam transmission for barriers in radiotherapy shielding x-ray facilities.
Reference Key
karoui2013montemedical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Karoui, Mohamed Karim;Kharrati, Hedi;
Journal Medical physics
Year 2013
DOI 10.1118/1.4811142
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.