A UHPLC-MS/MS method for simultaneous determination of twelve constituents from Erigeron breviscapus extract in rat plasma: Application to a pharmacokinetic study.

Clicks: 283
ID: 53307
2017
A rapid, sensitive and specific ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated to simultaneously determine the twelve major bioactive ingredients (neochlorogenic acid, chlorogenic acid, caffeic acid, cynarin, scopoletin, scutellarin, isochlorogenic acid A, apigenin-7-o-glucuronide, isochlorogenic acid C, scutellarein, luteolin, and apigenin) in rat plasma. Gallic acid and wogonoside were used as internal standards (IS1 and IS2). The plasma samples were pretreated and extracted by liquid-liquid extraction and protein precipitation with ethyl acetate-acetonitrile (95:5, v/v). Chromatographic separation was accomplished on Agilent ZORBAX RRHD Eclipse Plus C18 column (2.1mm×50mm, 1.8μm) utilizing 0.1% formic acid aqueous solution and acetonitrile as mobile phase under gradient conditions at a flow rate of 0.3mL·min. Mass spectrometric detection was performed in multiple reaction monitoring (MRM) mode using electrospray ionization (ESI) in positive and negative mode. The whole intra- and inter-day precision (as relative standard deviation) of all analytes were less than 11.03%, and the accuracy (as relative error) were in the range from -10.43% to 9.76% and from -10.14% to 10.33%. The lower limits of quantification (LLOQ) were 20, 3.0, 100, 7.0, 0.30, 2.0, 70, 1.0, 20, 30, 10, and 2.0ngmL for neochlorogenic acid, chlorogenic acid, caffeic acid, cynarin, scopoletin, scutellarin, isochlorogenic acid A, apigenin-7-o-glucuronide, isochlorogenic acid C, scutellarein, luteolin, and apigenin, respectively. Extraction recovery, matrix effect and stability were found to be the required limits. This method was selective and sensitive for the investigation of the pharmacokinetics of twelve constituents following oral administration to research study about in Erigeron breviscapus of clinical practices for separately analytes on rats.
Reference Key
tian2017ajournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Tian, Yuanyuan;Li, Qingqian;Zhou, Xinpeng;Pang, Qian;Xu, Yuanjin;
Journal journal of chromatography b, analytical technologies in the biomedical and life sciences
Year 2017
DOI S1570-0232(16)30700-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.