Oocyte donation in donors with levonorgestrel intrauterine device: a good match?
Clicks: 243
ID: 57088
2019
Does the levonorgestrel-releasing intrauterine device (LNG-IUD) influence cumulative live birth rate (CLBR) in oocyte donor cycles?Retrospective cohort study based on prospectively collected data from 1 May 2009 to 31 December 2017, without attrition, consisting of 491 consecutive cycles of vitrified oocyte donation, none lost to follow-up (unique donor-recipient pairs). All donors underwent ovarian stimulation using gonadotrophin releasing hormone (GnRH) antagonist co-treatment and GnRH agonist trigger. CLBR was chosen as primary outcome measure.In total, 103 (21.0%) cycles were carried out in donors carrying a LNG-IUD. In 388 (79.0%) cycles, no LNG-IUD was present. After confounder-adjustment, the use of an LNG-IUD did not have a statistically significant influence on CLBR.The LNG-IUD does not negatively affect CLBR.
Reference Key |
galvo2019oocytereproductive
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Galvão, Ana;Karakus, Gunes;Racca, Annalisa;Santos-Ribeiro, Samuel;De Munck, Neelke;Drakopoulos, Panagiotis;De Vos, Michel;Verheyen, Greta;Tournaye, Herman;Blockeel, Christophe; |
Journal | reproductive biomedicine online |
Year | 2019 |
DOI | S1472-6483(19)30586-3 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.