Validation of a fast liquid chromatography-UV method for the analysis of drugs used in combined cardiovascular therapy in human plasma.

Clicks: 231
ID: 96196
2009
Ultra-performance liquid chromatography (UPLC) was investigated as a faster alternative to high-performance liquid chromatography (HPLC) for the simultaneous analysis of drugs usually prescribed in cardiovascular therapy. Upon a previously developed and validated solid phase extraction (SPE)-HPLC-photodiode array (PDA)-fluorescence (FLR) method, separation of chlorthalidone (CLTD; diuretic), valsartan and its metabolite (VAL and VAL-M1 respectively; angiotensin II receptor antagonist drugs) and fluvastatin (FLUV; statin) was performed in human plasma using an RP C18 column (50mmx2.1mm, 1.7microm, Waters Acquity UPLC (BEH)) and a tunable UV-vis (TUV) detector. After method transfer, different system variables were modulated to study the evolution of responses of the analytes and the endogenous interferences. The improved method was fully validated and the results were compared with its precursor HPLC method relating to analysis time, efficiency and sensitivity. The studied compounds were separated in less than 8min and the method showed good linearity (20-3000microg/L for chlorthalidone, 110-1100microg/L for valsartan-M1, 67-1900microg/L for valsartan and 48-1100microg/L for fluvastatin), precision and accuracy. The proposed method was found to be reproducible (RSD<10%), accurate (RE<15%), robust and suitable for quantitative analysis of the studied drugs in plasma obtained from patients under combined cardiovascular treatment.
Reference Key
iriarte2009validationjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Iriarte, Gorka;Gonzalez, Oskar;Ferreirós, Nerea;Maguregui, Miren Itxaso;Alonso, Rosa Maria;Jiménez, Rosa Maria;
Journal journal of chromatography b, analytical technologies in the biomedical and life sciences
Year 2009
DOI 10.1016/j.jchromb.2009.07.018
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.